知識がなくても始められる、AIと共にある豊かな毎日。
AI Tool Review

Toolchanger Standby Temperature and Preheat Don’t Show Up in the Estimate — Changing OrcaSlicer 2.5 Settings and Reading the Wait Commands with AI

swiftwand

On a toolchanger, the standby temperature setting keeps the nozzles of tools that are not currently printing below the printing temperature. Lowering it makes the parked nozzles less likely to ooze while they wait in the dock. The trade-off is a wait to bring the temperature back up the next time that tool is used, which is why the slicer also offers a preheat setting that warms the next tool in advance. So what happens to the slicer’s time estimate when you make the standby drop deeper or the preheat longer? I checked whether the estimate can be used to compare settings that are meant to cut waiting.

This article contains affiliate links. As an Amazon Associate, we earn from qualifying purchases.

Using the CLI of OrcaSlicer 2.5.1 (the stable release published on November 14, 2026), I sliced a four-color model with the official profiles for the Prusa XL 5T, Prusa CORE One INDX 8T and Snapmaker U1. I changed one thing at a time — whether standby temperature (Ooze prevention) is on, the temperature variation, the preheat time in seconds, and the fixed value added to the estimate for every tool change (machine_tool_change_time) — and counted the estimated time and the number of temperature commands in the G-code. Every value comes from the slicer’s estimate and G-code counts; I did not print anything on real hardware. Each condition was run once.

Here is the result up front. In this run, no matter how I changed standby temperature and preheat, the estimated time for all three printers stayed the same down to the second. The only thing that changed was the number of M109 lines, which wait until the temperature is reached, and M104 lines, which do not wait. That matches my reading of the source: the OrcaSlicer 2.5.1 estimator does not add heating time for M109. What the estimate did include was the fixed value per tool change, and setting it to 0 shortened the estimates for the INDX 8T and U1. I also gave AI models the 70 lines around a tool change, and they identified the waiting lines in all 27 runs — but the questions were easy and the scores hit the ceiling. The effect of settings that reduce waiting cannot be compared using the slicer’s estimate.

目次
  1. Toolchanger standby temperature lowers the temperature of tools that are not in use
  2. Default values in the three printer profiles — standby temperature is off on the INDX 8T
  3. Temperature commands come from three places — standby temperature, preheat and the printer’s tool-change G-code
  4. OrcaSlicer 2.5.1 estimates add no heating time for M109
  5. Test conditions — slicing a four-color shape on three printers, changing one setting at a time
  6. Results — estimated time did not change; only the counts of M109 and M104 lines did
  7. What enters the estimate is the fixed value per change — setting it to 0 shortened the INDX 8T and U1
  8. Given the 70 lines around a tool change, AI found the waiting lines in all 27 runs
  9. IDEX/IQEX parallel printing is a separate setting from toolchanging
  10. Steps for tuning toolchanger standby temperature and preheat
  11. What this run can’t tell you
  12. Summary — judge toolchanger standby temperature and preheat by the G-code and the real machine, not the estimate
  13. Sources
忍者AdMax

Toolchanger standby temperature lowers the temperature of tools that are not in use

Toolchanger standby temperature lowers the temperature of tools that are not in use

In this article, a toolchanger means a machine that swaps between multiple tools to change colors or materials. The overall picture of the approach, and how it differs from nozzle switching and hotend swapping, is covered in What changed in multi-tool 3D printers — sorting out nozzle switching, hotend swapping and tool changing from the nine tools of the H3C (published 2026-11-23). Here I look at the OrcaSlicer settings that decide how temperature is handled before and after a tool change.

Standby temperature, temperature variation and idle temperature

OrcaSlicer’s standby temperature (Ooze prevention in the English UI; taredashi yokushi in the Japanese UI) lowers the temperature of inactive extruders. The tooltip in the source says “This option will drop the temperature of the inactive extruders to prevent oozing.” It is off by default. It also has no effect on printers that swap materials through a single nozzle (single_extruder_multi_material), even when enabled.

How far it drops is set by Temperature variation (key standby_temperature_delta). The default is −5 °C, and on standby the nozzle sits at the printing temperature plus this value. On the material side there is also an Idle temperature setting, and if it is not 0 it takes priority over the temperature variation. That order of priority is the same in the branches of the OrcaSlicer source and in the PrusaSlicer help for the XL: “The temperature in the idle temperature setting has priority over the temperature variation in the ooze prevention setting.”

Setting (English / Japanese UI label)KeyDefaultWhat it does
Standby temperature (Ooze prevention / taredashi yokushi)ooze_preventionOffLowers the temperature of tools not in use
Temperature variation (Temperature variation / ondo-sa)standby_temperature_delta−5 °COn standby, this difference is added to the printing temperature
Idle temperature (Idle temperature / aidoringu ondo; a filament setting)idle_temperature0 (off)If not 0, used as the standby temperature in preference to the temperature variation
Preheat (Preheat time / yonetsu jikan)preheat_time30 s (0–120 s)Inserts commands that warm the next tool in advance
Preheat steps (Preheat steps / yonetsu suteppu-su)preheat_steps1 (1–10)How many steps the preheat command is split into; only meaningful on the Prusa XL

The meaning of 0 differs from setting to setting, which makes it easy to mix up. An idle temperature of 0 means “off,” not “drop to 0 °C”; in that case the temperature variation is used. A temperature variation of 0 means “do not change the temperature,” and then no command to bring the temperature back and wait after a change is emitted either. Separately, for tools that are not used again in the print, OrcaSlicer writes a temperature-0 command (S0). That one means switching the heater off, and the 2.5.0 (alpha) release notes also say that finished tools are powered off rather than kept at standby temperature.

The PrusaSlicer help explains why you would lower it. With standby temperature disabled, every extruder stays at printing temperature for the whole print, which can lead to “significant oozing, material degradation in the melt zone, and possibly nozzle clogging.” Note that this sentence is about PrusaSlicer and the Prusa XL; it does not come from the OrcaSlicer documentation.

Preheat only kicks in when standby temperature is enabled

Preheat (Preheat time) warms the next tool while the current tool is still printing, to cut the wait after a change. The OrcaSlicer Wiki says “Orca will insert an M104 command to preheat the tool in advance.” In the source, it only works when standby temperature is enabled and the preheat time is greater than 0. In other words, if standby temperature is off, entering a preheat time inserts no commands.

Where the command goes is decided by a post-processing step that runs when the G-code is written. It is inserted at the point that lies the preheat time before the T line (the command that changes tools), measured in estimated time. So “120 seconds before” means 120 seconds before according to the estimate, not 120 seconds before on the real machine. The search backwards stops at the previous change to the same tool or at the start commands (G28, G29, PRINT_START, START_PRINT).

The syntax depends on the printer. On printers that OrcaSlicer identifies as a Prusa XL, it uses M104.1. A comment in the source describes this as a command that tells the XL the estimated time until that tool is used next. However, the comment says it was copied from the Prusa firmware source, and I did not check the firmware-side specification. On other printers it writes a non-waiting M104 with a comment of the form “preheat T(number) time: (seconds)s”. Preheat steps sets how many stages this M104.1 is split into, and the Wiki says “Only useful for the Prusa XL.” In the GUI, the item is shown in Developer mode.

According to the Bambu Lab announcement, the H3C reads the upcoming G-code and heats the next nozzle before the current tool’s segment ends (Active Pre-Heat). That puts the mechanism in a different place from OrcaSlicer’s preheat, where the slicer writes the commands into the G-code. The H3C is sliced in Bambu Studio and is not part of this run.

One more: the 2.5.0 (alpha) release notes also list a setting that picks up the new tool without waiting for it to reach printing temperature and lets it wait beside the prime tower (wait_for_temp_on_wipe_tower, off by default). Its description assumes that neither the firmware nor the tool-change macro waits for temperature on its own. None of the three profiles uses this setting. The tool-change G-code of the XL 5T and U1 does its own waiting, so it is not something to combine with this setting.

Default values in the three printer profiles — standby temperature is off on the INDX 8T

Default values in the three printer profiles — standby temperature is off on the INDX 8T

OrcaSlicer 2.5.1 is a maintenance update to 2.5.0 (published 2026-11-07), and its release notes list no changes to how standby temperature or preheat work. I traced the inheritance in its bundled profiles to confirm the defaults for the three printers. Process values are those of each printer’s default process (default_print_profile).

ItemPrusa XL 5T 0.4CORE One INDX 8T HF 0.4Snapmaker U1 0.4
Standby temperatureOnOffOn
Temperature variation−40 °C−5 °C (left at the root process default)−150 °C
Preheat120 s, 10 stepsNot specified (30 s default if enabled)30 s, 1 step
Preheat commandM104.1M104M104
Fixed value per change (machine_tool_change_time)0 s (not set)12.5 s5 s
G-code flavor (gcode_flavor)marlin2marlin2klipper

The XL 5T enables standby temperature, sets the temperature variation to −40 °C, and sets preheat to the maximum of 120 seconds in 10 steps. With 10 steps, the preheat commands are spread out every 120 ÷ 10 = 12 seconds. OrcaSlicer treats a printer as an XL if its printer_notes contain both PRINTER_VENDOR_PRUSA3D and PRINTER_MODEL_XL. The PRINTER_MODEL_XLIS of the XL 5T contains the latter, so preheat is written as M104.1. With the default filament (Generic PLA @Prusa XL, 210 °C), the standby temperature from the second layer on is 210 − 40 = 170 °C. The first layer uses the first-layer temperature, so it is not part of this calculation.

On the CORE One INDX 8T (profile: HF 0.4 nozzle), standby temperature is off in the default process. The default process, 0.20mm Balanced, inherits from the MK4S family of processes, and process_common_mk4s within that chain sets ooze_prevention to 0. So the absence of standby and preheat commands on an INDX 8T left at its defaults is not a bug. If you enable it, the temperature variation is the root process value of −5 °C, and preheat falls back to the 30-second default because the process does not specify one. With the default filament (Generic PLA @Prusa CORE One INDX, 215 °C), enabling it gives a standby temperature of 215 − 5 = 210 °C.

The Snapmaker U1 enables standby temperature, sets the temperature variation to −150 °C and sets preheat to 30 seconds. The U1 process overrides the root process value of −5 °C with −150 °C. The default filament that the U1 machine profile points to through inheritance (Snapmaker PLA) does not list the U1 among its compatible printers. So for this run I used Generic PLA @U1 0.4 nozzle, with settings I expanded from the inheritance chain myself (210 °C). With those settings, the standby temperature from the second layer on is 210 − 150 = 60 °C. However, following the inheritance in the bundled profiles, this filament inherits from Generic PLA @System in OrcaFilamentLibrary, and the nozzle temperature becomes 220 °C (70 °C on standby). The only difference is the absolute standby temperature; the conclusions about estimated time and M109/M104 line counts do not change. All the standby temperatures given here are calculated from profile values. In this run I did not tally the temperature values written in the G-code.

The fixed value per change also differs by printer: the XL 5T has no setting and uses the default of 0 seconds, the INDX 8T uses 12.5 seconds and the U1 uses 5 seconds. These are all values for the estimate, not measurements of real tool-change times. This difference matters for how you read the results in later sections.

Temperature commands come from three places — standby temperature, preheat and the printer’s tool-change G-code

Temperature commands come from three places — standby temperature, preheat and the printer’s tool-change G-code

Commands that handle temperature around a tool change come from three sources. The ones that write M109, which waits until the temperature is reached, are (a) after the change and (c); (b) preheat only writes commands that do not wait. Laid out as G-code lines, they look like this, with numbers filling in the temperature, tool number and seconds.

(a) OrcaSlicer standby temperature
Before the change  M104 S<temp> T<tool> ; set nozzle temperature ;cooldown
After the change   M109 S<temp> T<tool> ; set nozzle temperature and wait for it to be reached
(b) OrcaSlicer preheat
XL                 M104.1 T<tool> P<seconds> S<temp>
Other than XL      M104 S<temp> T<tool> ; preheat T<tool> time: <seconds>s
(c) Tool-change G-code in the printer profile
XL, U1             M109 S<temp> (before picking up the new tool)
INDX               M109 C<temp> (at the cleaning position)

OrcaSlicer writes the (a) standby commands before and after its tool-change routine. Before the change, it lowers the finished tool to standby temperature with a non-waiting M104 and marks the end of the line with “;cooldown”. After the change, it writes an M109 that brings the new tool back to printing temperature and waits until it gets there. In the source, this M109 is only emitted when the temperature variation is not 0. At the start of the print, too, every tool except the first one used is set to standby temperature.

The (b) preheat commands, as described in the previous section, are non-waiting commands inserted at a point found by stepping back in estimated time from the T line: M104.1 on the XL, and M104 on other printers.

(c) is written by the tool-change G-code (Change filament G-code) in the printer profile. On the XL 5T and U1, it writes an M109 S… that waits for printing temperature before picking up the new tool. The U1 then writes M400 and the T line, and when switching to any tool other than the first one used, it calls a pre-extrusion macro (SM_PRINT_PREEXTRUDE_FILAMENT) after the change. The INDX inserts M104 commands that raise and lower the temperature after picking up the tool, and waits at the cleaning position with M109 C…. The M109 with a C parameter and the contents of the U1 macro are firmware-side behavior that I did not verify here.

The INDX tool-change G-code also contains extrusion commands at the cleaning position. Even on a printer that changes whole tools, some material is pushed out and discarded at every change.

The key point is that (c) is separate from the OrcaSlicer standby temperature setting. Disabling standby temperature leaves the M109 in the printer’s tool-change G-code in place. Put another way, even if the G-code waits for temperature at every change, that wait did not necessarily come from the standby temperature setting. If you only look at the standby setting while trying to cut waiting, you will miss this third source.

OrcaSlicer 2.5.1 estimates add no heating time for M109

OrcaSlicer 2.5.1 estimates add no heating time for M109

The estimated time in OrcaSlicer is calculated by the code that reads the G-code line by line (GCodeProcessor). Reading GCodeProcessor.cpp at tag v2.5.1, the handler for M109 only records the target temperature; there is no part that calculates how long heating takes. With the Klipper flavor it calls a synchronization routine, but the default number of seconds it adds there is 0. The non-waiting M104 also just records the target temperature.

What does get added to the estimate is the following.

  • Movement time
  • Waits written in G4 and M400 (S in seconds, P in milliseconds)
  • The fixed value per tool change (machine_tool_change_time). The same number of seconds is added for each change, regardless of temperature or distance
  • The fixed value for loading and unloading filament, added when the material in an extruder changes
  • 720 seconds for an M191 chamber-heating wait above 40 °C

The description of machine_tool_change_time ends with “For statistics only.” That means the value writes no commands into the G-code and is used only for the estimate; the default is 0 seconds. Also, M400 does nothing for flavors other than Klipper when no seconds are given. In this run I did not count whether the G-code of the three printers contained M191.

That leads to a prediction before running anything: however standby temperature and preheat are changed, the estimate should stay the same, and only the G-code commands should change. The U1 is the one exception in principle. It uses the Klipper flavor, so M109 and M400 trigger synchronization in the estimator, which leaves room for the estimate to shift slightly when the number of commands changes, for reasons unrelated to heating.

Test conditions — slicing a four-color shape on three printers, changing one setting at a time

Test conditions — slicing a four-color shape on three printers, changing one setting at a time

The model is a cylinder 40mm in diameter and 10mm tall, divided from the center into four sector-shaped quarters and painted in four colors. Every layer contains all four colors, so there are many tool changes; with this shape, all three printers came out at 150 changes. The change count is the value in the change-count line of the G-code (total filament change). This shape and counting method are the same as when I compared seven printers in How much material do multicolor prints waste on different printers? Slicing the same model with seven printer profiles and counting purges and changes (published 2026-11-24).

The printers are the Prusa XL 5T 0.4 nozzle, Prusa CORE One INDX 8T HF 0.4 nozzle and Snapmaker U1 (0.4 nozzle). I expanded the inheritance of the official OrcaSlicer 2.5.1 profiles and passed the result to the CLI. Because the CLI stopped when given the profiles as they were, two things were changed in common for every condition. First, the U1 build plate type was changed from the default Textured PEI Plate to High Temp Plate. That is because, in the settings I expanded for the U1 filament (Generic PLA @U1 0.4 nozzle), the bed temperature was only filled in for High Temp Plate (following the bundled inheritance, Textured PEI Plate also gets 55 °C). Second, for the INDX 8T and U1, I took one value from each list of per-nozzle-type values (High Flow for the INDX 8T, Standard for the U1), the same as choosing a nozzle type in the GUI. From this baseline, I changed only the settings in the table below.

ConditionSetting changed
baseNothing (profile values)
ooze0 / ooze1Standby temperature off / on
sb0 / sb40 / sb100Standby temperature on, temperature variation 0 / −40 / −100 °C
pre0 / pre60 / pre240Standby temperature on, preheat 0 / 60 / 240 s (240 s exceeds the 120 s maximum of the setting)
mtc0Fixed value per change in the printer profile (machine_tool_change_time) set to 0 s

I counted the estimated-time line of the G-code (the normal mode value of estimated printing time), the number of tool changes, and the number of lines starting with M109 and with M104. The M104 lines include the M104.1 preheat lines of the XL. I did not break M109 and M104 down by source (a)–(c) above.

OrcaSlicer 2.5.1 came from the official portable zip (commit eef7710c, SHA-256 f7319478…15e8), which I extracted and used through the CLI only. It is licensed under AGPL-3.0 and free to use. The PC was a Windows 11 Pro machine with an Intel Core Ultra 7 265F, 63.7 GB of RAM and an RTX 5070 Ti 16 GB. No GUI app, sign-in or printer connection was used.

Results — estimated time did not change; only the counts of M109 and M104 lines did

Results — estimated time did not change; only the counts of M109 and M104 lines did

Here are the results for the three printers. The number of tool changes was 150 in every condition except pre240, which stopped.

Prusa XL 5T:

ConditionStandby temperatureTemperature variation (°C)Preheat (s)Estimated timeM109 linesM104 lines
baseOn−4012053m 18s307827
ooze0Off−4012053m 18s15617
ooze1On−4012053m 18s307827
sb0On012053m 18s156823
sb40On−4012053m 18s307827
sb100On−10012053m 18s307827
pre0On−40053m 18s307164
pre60On−406053m 18s3071377
pre240On−40240Stopped——
mtc0On−4012053m 18s307827

CORE One INDX 8T (“Not specified” preheat means the 30-second default when standby temperature is on):

ConditionStandby temperatureTemperature variation (°C)Preheat (s)Estimated timeM109 linesM104 lines
baseOff−5Not specified1h 2m 30s303463
ooze0Off−5Not specified1h 2m 30s303463
ooze1On−5Not specified1h 2m 30s454759
sb0On0Not specified1h 2m 30s303612
sb40On−40Not specified1h 2m 30s454759
sb100On−100Not specified1h 2m 30s454759
pre0On−501h 2m 30s454610
pre60On−5601h 2m 30s454667
pre240On−5240Stopped——
mtc0Off−5Not specified31m 3s303463

Snapmaker U1:

ConditionStandby temperatureTemperature variation (°C)Preheat (s)Estimated timeM109 linesM104 lines
baseOn−1503056m 20s306309
ooze0Off−1503056m 20s15512
ooze1On−1503056m 20s306309
sb0On03056m 20s155162
sb40On−403056m 20s306309
sb100On−1003056m 20s306309
pre0On−150056m 20s306159
pre60On−1506056m 20s306216
pre240On−150240Stopped——
mtc0On−1503043m 50s306309

Estimated time stayed the same however standby temperature and preheat were changed

Excluding mtc0, where the fixed value was changed, and pre240, which stopped, the estimated times were 53m 18s for the XL 5T, 1h 2m 30s for the INDX 8T and 56m 20s for the U1, identical across conditions. Turning standby temperature off, deepening the temperature variation to −100 °C, or setting preheat to 0 seconds did not move the estimate by a single second. The U1, with its Klipper flavor, had room for the estimate to shift slightly with the number of commands, but no difference appeared in this run.

This is exactly what the source reading predicts: the estimate does not add heating time for M109. For example, changing the temperature variation from −40 °C to −100 °C widens the range the G-code has to recover, from standby back to printing temperature, from 40 °C to 100 °C. Even so, the estimate was the same. Neither the extra waiting from a deeper standby drop nor the reduced waiting from preheat shows up in the slicer’s estimate.

Turning standby off removed 151 M109 lines, and the remaining M109 lines did not go away

In ooze0, with standby temperature disabled, M109 dropped from 307 → 156 on the XL 5T and from 306 → 155 on the U1. On the INDX 8T, where it is off by default, the direction is reversed: enabling it in ooze1 raised M109 from 303 → 454. The difference is 151 lines on all three printers (307 − 156, 306 − 155, 454 − 303), one more than the 150 changes. I did not check line by line where that extra line comes from.

Based on the source, turning standby temperature off should remove (a) and (b), while the (c) commands in the printer’s tool-change G-code remain. In fact, with standby off, 156 M109 lines remained on the XL 5T, 155 on the U1 and 303 on the INDX 8T. For M104, the INDX 8T has 463 lines, compared with 17 on the XL 5T and 12 on the U1; the INDX tool-change G-code contains M104 commands that raise and lower the temperature after picking up a tool. I did not count M109 and M104 by source, but the way the line counts moved is consistent with this prediction.

So turning off the standby temperature setting did not remove the commands that wait for temperature at every change from the G-code. On the XL 5T and U1, the printer’s tool-change G-code itself contains a command that waits for printing temperature before picking up the new tool.

With a temperature variation of 0, no wait-to-recover command was emitted after the change

In sb0, with standby temperature still on but the temperature variation at 0, M109 came out the same as with standby off (XL 5T 156, INDX 8T 303, U1 155). In the source, a temperature variation of 0 means no M109 is written after the change, and the counts in this run match that branch.

On the other hand, sb0 had more M104 lines (823 on the XL 5T, 612 on the INDX 8T and 162 on the U1) than with standby off (17, 463 and 12). In the source, preheat is still inserted when standby temperature is on, even if the temperature variation is 0. But because I did not count M104 by type, I have not verified what the extra lines consist of.

Between the −40 °C and −100 °C conditions, the line counts were identical: M109 307 and M104 827 on the XL 5T, 454 and 759 on the INDX 8T, and 306 and 309 on the U1. In the source, the size of the variation changes the temperature written in the commands, not the number of lines. I did not tally the temperature values in this run, so the tables do not show which temperatures were written.

Changing preheat moved only M104, and at 60 seconds the direction split by printer

In pre0, with preheat set to 0 seconds, M109 did not change and only M104 fell: 827 → 164 on the XL 5T and 309 → 159 on the U1. The INDX 8T fell to 610, compared with 759 in ooze1, where preheat is the default 30 seconds. The larger drop on the XL 5T fits its setting of writing preheat as M104.1 split into up to 10 steps.

In pre60, with preheat at 60 seconds, the direction split. On the XL 5T, where this shortened preheat from 120 to 60 seconds, M104 rose from 827 → 1377. Conversely, on the INDX 8T and U1, where this lengthened preheat from 30 to 60 seconds, M104 fell from 759 → 667 and from 309 → 216. A longer preheat does not necessarily mean more command lines. Why this happened cannot be told from this run, because I did not count lines by type.

In pre240, with preheat at 240 seconds, the CLI stopped on all three printers and produced no G-code. 240 seconds exceeds the 120-second maximum of the setting. The exit code was 4294967278 (−18 when read as a signed number), which in my reading of the source corresponds to the code returned when a setting value is out of range (CLI_INVALID_VALUES_IN_3MF). I did not record standard error.

Counting M109 and M104 lines in G-code is the kind of job that becomes easy to repeat once it is a short Python script. This book is a practical introduction to scripting tasks like that.

Paperback, 3rd edition (No Starch Press, May 2025) on Amazon.com

What enters the estimate is the fixed value per change — setting it to 0 shortened the INDX 8T and U1

What enters the estimate is the fixed value per change — setting it to 0 shortened the INDX 8T and U1

In mtc0, I set only the machine_tool_change_time of each printer to 0 seconds. The INDX 8T dropped from 1h 2m 30s → 31m 3s, and the U1 from 56m 20s → 43m 50s. The XL 5T stayed at 53m 18s, which is expected because its value was already 0 seconds.

Working out the difference, the U1 lost 56 min 20 s − 43 min 50 s = 12 min 30 s (750 seconds), which matches 150 changes × 5 seconds = 750 seconds exactly. The INDX 8T lost 1 h 2 min 30 s − 31 min 3 s = 31 min 27 s (1,887 seconds), 12 seconds more than 150 × 12.5 seconds = 1,875 seconds (31 min 15 s). In the INDX 8T G-code, there is also a switch from T0 to T1 in the start section (line 124), which makes 151 switches together with the 150 in the body. 151 × 12.5 seconds = 1,887.5 seconds, which matches the 1,887-second difference. This suggests that the estimate also adds the fixed value for the switch in the start section. Even so, about half of the 1h 2m 30s estimate for the INDX 8T was this fixed value.

This fixed value is the same number of seconds per change regardless of temperature or distance, and it is not a measurement of real change time. Deepening the standby drop so that the recovery range widens, or lengthening preheat, leaves the tool-change time in the estimate at this fixed value. That is why comparing settings that reduce waiting by their estimates shows no difference. What you can compare is the number of commands written in the G-code and the values in those commands (the standby temperature, and how many seconds ahead preheat starts).

The fact that each printer puts different things into the estimate was also a caveat on reading the table when I lined up estimated times for seven printers in How much material do multicolor prints waste on different printers? (published 2026-11-24). There, for example, the added time of the XL 5T for four colors on shape A was shorter than that of the other two Orca printers, but the XL 5T counts each change as 0 seconds. The mtc0 result here fits that reading. Some printers see their estimate nearly halve just from setting the fixed value to 0, and others do not move at all. So lining up estimated times across printers does not compare how fast they change tools.

Rated tool-change times are not the same thing as the fixed value in the profile

It is better not to read the 12.5 or 5 seconds in the profiles as the manufacturers’ rated tool-change times. Each manufacturer states the conditions behind its rated value differently. Here I list them one at a time with their conditions, without ranking them against each other.

  • Bondtech INDX: about 14 seconds for a change including heating (“Complete tool change incl. heat-up: ~14s”), with a note that it depends heavily on temperature, priming, travel and so on. This is the value for the Bondtech INDX, not for the Prusa kit for the CORE One
  • Snapmaker U1: “Direct Swaps in 5s.” with a note that this is a typical value from Snapmaker testing, for reference. It says the value is with preheated toolheads, but no temperature is given
  • Bambu Lab H3C: the announcement says it can “change material in under 6 seconds” and gets back to the model in 6 seconds including priming. The H3C change time is described in two ways, which I sorted out in What changed in multi-tool 3D printers (published 2026-11-23)

For the U1, the fixed value in the profile and the rated value are both 5 seconds. Still, the profile value is a fixed number for the estimate, and I did not verify how the two relate.

Given the 70 lines around a tool change, AI found the waiting lines in all 27 runs

Given the 70 lines around a tool change, AI found the waiting lines in all 27 runs

Reading G-code to find where the printer waits is one of the jobs you might want to hand to AI. So from the base G-code I extracted the 70 lines around one tool change (the 2nd change for the XL 5T and U1, the 8th for the INDX 8T), numbered the lines and gave them to AI. There were two questions.

  • Q1: On which lines does the nozzle stop and wait until it reaches the target temperature? (answer with line numbers)
  • Q2: Does the OrcaSlicer estimated time include the heating wait at a tool change? (answer yes or no)

The correct answers were set by a script, not by AI. For Q1, the answer is the M109 lines in the excerpt: lines 25 and 36 for the XL 5T, lines 24 and 32 for the U1, and lines 34 and 54 for the INDX 8T. For Q2 the answer is “no,” based both on the source reading and on the results in the previous section.

I used two AI setups. One was claude -p (running Claude Code non-interactively), and every response recorded the model ID claude-sonnet-5-5 (Claude Sonnet 5.5). The other was gemma4:12b (Google Gemma 4 12B, 11.9B parameters, Q4_K_M quantization, digest 6114515d63c1), run through Ollama on the local RTX 5070 Ti. For gemma4:12b I separated a condition without thinking and a condition with thinking. Each was run three times, for a total of 27 runs across the three printers.

PrinterCorrect M109 linesclaude -pgemma4:12b (no thinking)gemma4:12b (thinking)
Prusa XL 5T25, 363 of 33 of 33 of 3
Snapmaker U124, 323 of 33 of 33 of 3
CORE One INDX 8T34, 543 of 33 of 33 of 3

“3 of 3” in the table is the number of runs in which the set of lines given for Q1 matched the answer and Q2 was answered “no.” None of the 27 runs missed a line or added an extra one. The cost returned by claude -p was $0.0033266–$0.011036 per run. gemma4:12b ran locally, so there was no API cost (electricity not included).

The questions were easy and the scores hit the ceiling

All 27 runs being correct does not mean I measured how well AI reads G-code. The excerpts were only 70 lines, and anyone who knows that M109 waits for temperature can answer Q1. Q2 was a two-way choice. On a test where everyone gets full marks, differences between models are invisible. The accurate reading of this run is that the questions were too easy and hit the ceiling.

In addition, this scoring cannot tell whether the correct Q2 answers came from knowing the OrcaSlicer source or from a lucky guess. And the question at the core of this article, which of (a) standby temperature, (b) preheat or (c) the printer’s tool-change G-code a temperature command came from, and in particular whether a waiting M109 came from (a) or (c), was not put to the AI. So whether you can hand off identifying the source to AI cannot be told from this run.

What to hand to AI, and what not to

What this run supports is narrow. Finding the lines that wait for temperature in a few dozen lines around a change, and reading that M109 waits while M104 does not, were not missed by any of the three conditions in these 27 runs. When checking what is written at every change in a long G-code file, having AI find the lines can save effort. But check the lines it gives by searching the G-code yourself.

Conversely, it is better not to have AI estimate how many seconds the wait takes. This run has no correct answer for the seconds: the OrcaSlicer estimate does not count heating waits, and I did not measure on real hardware. Even if AI gives a plausible number of seconds, there is nothing to check it against. Let AI read line positions and the meaning of commands, and look at the length of the wait on the real machine. That is as far as this run lets me draw the line.

If you want to design questions like these so that a model’s answers can actually be checked, this book on prompt engineering covers how to frame and evaluate them.

USD 54.51 on Amazon.com (as of 2026/09/22)

IDEX/IQEX parallel printing is a separate setting from toolchanging

IDEX/IQEX parallel printing is a separate setting from toolchanging

OrcaSlicer 2.5 also gained a feature that goes in a different direction from tool changing. The release notes for the 2.5.0 stable release say it can “print two to four parts at once on IDEX and IQEX printers.” In Slicer plugins arrive in OrcaSlicer 2.5 and PrusaSlicer 3.0 — what changed in the two previews, and what is still undecided (published 2026-10-26), I mentioned this in one sentence as one of the new features of the 2.5.0 alpha. After the alpha, the feature made it into the 2.5.0 stable release (published 2026-11-07).

The number of parts printed at once is set by the number of carriages: two on an ordinary IDEX, and up to four on IQEX printers or machines with four carriages on one gantry. IQEX (independent quad extruder) refers to a machine with two gantries, each carrying two carriages. In the bundled 2.5.1 profiles, the printers with this feature enabled (is_imex set to 1) are the Vivedino Xplorer IDEX, Dual Gantry and IQEX, each with 0.4, 0.6 and 0.8 mm profiles. IDEX has three modes (primary, copy and mirror), and IQEX has seven.

The mechanism is that OrcaSlicer slices only the one part for T0 (plus the part for a carriage in the Span role, if there is one), and the printer firmware has the other carriages repeat the motion of T0 either as it is (copy) or mirrored (mirror). The Wiki says “OrcaSlicer does not move the other carriages itself.” and requires the firmware to have copy and mirror modes built in. So the G-code toolpaths and the estimate cover one part, while the other carriages print the same part or its mirror image.

The Wiki also spells out the limits. Toolpath collisions are not checked layer by layer, and brims and skirts are not checked against the zones. The slicer does not make sure the carriages will not hit each other.

And this feature is not meant for toolchangers. The settings page says to leave it disabled on printers whose toolheads print only one at a time, meaning ordinary dual-extruder printers and toolchangers. The XL 5T, INDX 8T and U1 are not targets for parallel printing, and this run did not slice with parallel-printing profiles.

Steps for tuning toolchanger standby temperature and preheat

Steps for tuning toolchanger standby temperature and preheat

From these results, here are the steps for tuning standby temperature and preheat on your own toolchanger. In the Japanese translation file at tag v2.5.1, the Japanese UI labels are ondo-sa for temperature variation, yonetsu jikan for preheat, yonetsu suteppu-su for preheat steps, aidoringu ondo for idle temperature, and tsuru kokan jikan for the fixed value per change (machine_tool_change_time). The translation file flags ondo-sa as needing review (Needs human review), so the wording may change from version to version.

1. Check the defaults in your printer profile

First, check whether standby temperature is enabled in the process for your printer: the Enable option under Ooze prevention in the English UI (yukoka under taredashi yokushi in the Japanese UI). In the bundled OrcaSlicer 2.5.1 profiles, it was on for the XL 5T and U1 and off for the INDX 8T. If you want to use preheat on the INDX 8T, enable standby temperature first; otherwise no preheat commands are inserted. Preheat steps is shown only in Developer mode and only matters on the Prusa XL. The maximum preheat time is 120 seconds.

2. Separate the sources of temperature commands in the G-code

Next, search the sliced G-code to see which commands sit around each change. The commands OrcaSlicer writes carry marker comments, so you can find them with the following strings.

;cooldown     Non-waiting M104 written by standby temperature before a change
M104.1        Preheat (Prusa XL)
; preheat T   Preheat (printers other than the XL)
M109          Waits until the temperature is reached (tell the source from the surrounding lines)

On the XL 5T and U1, the M109 written by the printer’s tool-change G-code comes before the T line that picks up the new tool. Comparing it with the surrounding lines gives you a clue for telling it apart from the M109 that (a) standby temperature writes after the change. You can have AI read around the change and find these lines, but check the lines it gives with a search. In this run AI got all 27 short excerpts right, but telling the sources apart was not tested.

3. Do not judge settings by estimated time

However standby temperature and preheat were changed, the OrcaSlicer estimate did not change. So avoid judging whether waiting went down from differences in the estimate. What you can compare are values written in the G-code: the number of M109 and M104 lines, the standby temperature, and how many seconds ahead preheat starts. Whether the actual wait went down can only be confirmed by watching how the real machine pauses around a change.

If you want the estimate to be closer to your own machine, one option is to put a value you have checked on your machine into the fixed value per change (machine_tool_change_time). This setting writes no commands into the G-code and is used only for the estimate (its description says “For statistics only”). In the mtc0 condition of this run, the INDX 8T and U1 estimates shrank, but all three printers had the same M109 and M104 line counts as base.

4. Choose the temperature variation by looking at both ooze and the recovery range

A deeper temperature variation lowers the standby temperature but widens the range to recover when the tool is used. For example, with the default filament and temperature variation of the XL 5T, the tool waits at 170 °C from the second layer on and returns to 210 °C when used. The −150 °C in the U1 profile works out to waiting at 60 °C with the Generic PLA @U1 0.4 nozzle settings used in this run (210 °C), or 70 °C with the 220 °C from the bundled inheritance. Which range is right depends on the material and the machine, and cannot be decided from the slicer’s estimate. Preheat time is the same: the seconds in the estimate only decide where the early heating command goes.

How much a parked nozzle oozes, and how long it takes to recover, depends on the filament. It helps to run these checks first with one common PLA you know well before moving on to other materials.

USD 26.98 on Amazon.com (as of 2026/09/21)

What this run can’t tell you

What this run can’t tell you
  • One run per condition, slicer estimates and G-code counts: I did not print on real hardware. Wait times in seconds, the amount of ooze and actual heating were not measured
  • One model: only a 40mm-diameter, 10mm-tall cylinder split into four colors, with 150 changes. Models with a different color order and conditions with a different number of colors were not tried
  • Range of profiles: only the XL 5T 0.4 mm, INDX 8T HF 0.4 and U1 0.4 mm profiles were used. The INDX 4T, other nozzle diameters and other printers were not used. The H3C is sliced in Bambu Studio and is not included
  • Counting method: I only counted lines starting with M109 and M104, without splitting them by source (a)–(c). The temperature values written in the commands and how many seconds ahead preheat starts were not tallied
  • Values whose cause I did not check: the M109 difference of 151 lines, one more than the number of changes, and the printers where M104 fell when preheat was set to 60 seconds
  • The condition that stopped: a 240-second preheat exceeds the 120-second maximum, and all three printers stopped. The reason is based on my reading of the source (the exit code returned when the range check fails); I did not record standard error
  • Firmware-side commands: how the firmware handles the INDX M109 C… and M104.1, and the contents of the U1 macro, were not checked
  • The AI questions: the excerpt was 70 lines from one place per printer, the questions were easy, and the scores hit the ceiling. Telling apart where a waiting command came from was not asked. The models were only claude-sonnet-5-5 and gemma4:12b
  • Parallel printing: I did not slice with IDEX/IQEX profiles. That section is based on the OrcaSlicer Wiki, release notes and bundled profiles, and does not cover the Vivedino Xplorer printers themselves
  • UI labels: the Japanese item names were checked in the translation file at tag v2.5.1; I did not open the UI itself

Summary — judge toolchanger standby temperature and preheat by the G-code and the real machine, not the estimate

Summary — judge toolchanger standby temperature and preheat by the G-code and the real machine, not the estimate
  • Using the OrcaSlicer 2.5.1 CLI with the official profiles for the Prusa XL 5T, CORE One INDX 8T and Snapmaker U1, I sliced a four-color shape and changed standby temperature, temperature variation, preheat and the fixed value per change one at a time. All values are slicer estimates and G-code counts; nothing was printed
  • In this run, however standby temperature and preheat were changed, the estimated time stayed at 53m 18s for the XL 5T, 1h 2m 30s for the INDX 8T and 56m 20s for the U1. Only the number of M109 and M104 lines changed
  • The OrcaSlicer 2.5.1 estimate does not add heating time for M109. What goes into the estimate is the fixed value per tool change; setting it to 0 shortened the INDX 8T to 31m 3s and the U1 to 43m 50s
  • Temperature commands come from three places: standby temperature, preheat and the printer’s tool-change G-code. The waiting M109 is written by standby temperature (after the change) and by the printer’s tool-change G-code, while preheat writes only commands that do not wait. Turning standby temperature off left the M109 in the printer’s tool-change G-code in place
  • Toolchanger standby temperature was off in the default process of the INDX 8T. Unless you enable it, no preheat commands are inserted either
  • Given the 70 lines around a change, all 27 runs of claude -p and gemma4:12b (with and without thinking) identified the waiting lines and answered that the estimate does not include heating waits. But the questions were easy and the scores hit the ceiling
  • Let AI find lines and read what commands mean, and check its answers with a search. For the length of the wait in seconds, rely on neither AI nor the slicer estimate; look at the real machine

For general multi-material settings beyond standby temperature and preheat, such as purge volumes and how to split support materials, see Multi-material slicing in practice 2026 — purge, support and material interface settings (published 2026-07-04).

Sources

ブラウザだけでできる本格的なAI画像生成【ConoHa AI Canvas】
ABOUT ME
swiftwand
swiftwand
AIを使って、毎日の生活をもっと快適にするアイデアや将来像を発信しています。 初心者にもわかりやすく、すぐに取り入れられる実践的な情報をお届けします。 Sharing ideas and visions for a better daily life with AI. Practical tips that anyone can start using right away.